QTP - Quick Guide



QTP - Introduction

QTP stands for QuickTest Professional, a product of Hewlett Packard (HP). This tool helps testers to perform an automated functional testing seamlessly, without monitoring, once script development is complete.

HP QTP uses Visual Basic Scripting (VBScript) for automating the applications. The Scripting Engine need not be installed exclusively, as it is available as a part of the Windows OS. The Current version of VBScript is 5.8, which is available as a part of Win 7. VBScript is NOT an object-oriented language but an object-based language.

Testing Tools

Tools from a software testing context, can be defined as a product that supports one or more test activities right from planning, requirements, creating a build, test execution, defect logging and test analysis.

Classification of Tools

Tools can be classified based on several parameters. It includes −

  • The purpose of the tool
  • The activities that are supported within the tool
  • The type/level of testing it supports.
  • The kind of licensing (open source, freeware, commercial)
  • The technology used

Types of Tools

Sr.No. Tool Type Used for Used by
1 Test Management Tool Test Managing, scheduling, defect logging, tracking and analysis. Testers
2 Configuration management tool For Implementation, execution, tracking changes All Team members
3 Static Analysis Tools Static Testing Developers
4 Test data Preperation Tools Analysis and Design, Test data generation Testers
5 Test Execution Tools Implementation, Execution Testers
6 Test Comparators Comparing expected and actual results All Team members
7 Coverage measurement tools Provides structural coverage Developers
8 Performance Testing tools Monitoring the performance, response time Testers
9 Project planning and Tracking Tools For Planning Project Managers
10 Incident Management Tools For managing the tests Testers

Where QTP Fits in?

QTP is a Functional testing tool, which is best suited for regression testing of the applications. QTP is a licensed/commercial tool owned by HP, which is one of the most popular tools available in the market. It compares the actual and the expected result and reports the results in the execution summary.

QTP – History and Evolution

HP Quick Test Professional was originally owned by Mercury Interactive and it was acquired by HP. Its original name was Astra Quick Test and later named as Quick Test Professional but the latest version is known as Unified Functional Tester (UFT).

Version History

Now let us take a look at the version history of QTP.

Versions Timelines
Astra Quick Test v1.0 to v5.5 - Mercury Interactive May 1998 to Aug 2001
QuickTest Professional v6.5 to v9.0 - Mercury Interactive Sep 2003 to Apr 2006
Hp-QuickTest Professional v9.1 to v11.0 - Acquired and Released by HP Feb 2007 to Sep 2010
Hp-Unified Functional Testing v11.5 to v11.53 2012 to Nov 2013

Advantages

  • Developing automated tests using VBScript does not require a highly skilled coder and is relatively easy when compared to other object oriented programming languages.

  • Easy to use, ease of navigation, results validation, and Report generation.

  • Readily Integrated with Test Management Tool (Hp-Quality Center) which enables easy scheduling and monitoring.

  • Can also be used for Mobile Application Testing.

  • Since it is an HP product, full support is provided by HP and by its forums for addressing technical issues.

Disadvantages

  • Unlike Selenium, QTP works in Windows operating system only.

  • Not all versions of Browsers are supported and the testers need to wait for the patch to be released for each one of the major versions.

  • Having said, that it is a commercial tool, the licensing cost is very high.

  • Even though scripting time is less, the execution time is relatively higher as it puts load on the CPU & RAM.

QTP - Automated Testing Process

For any automated tool implementation, the following are the phases/stages of it. Each one of the stages corresponds to a particular activity and each phase has a definite outcome.

Automated Testing Process
  • Test Automation Feasibility Analysis − First step is to check if the application can be automated or not. Not all applications can be automated due to its limitations.

  • Appropriate Tool Selection − The next most important step is the selection of tools. It depends on the technology in which the application is built, its features and usage.

  • Evaluate the suitable framework − Upon selecting the tool, the next activity is to select a suitable framework. There are various kinds of frameworks and each framework has its own significance. We will deal with frameworks in detail later in this tutorial.

  • Build Proof of Concept − Proof of Concept (POC) is developed with an end-to-end scenario to evaluate if the tool can support the automation of the application. It is performed with an end-to-end scenario, which ensures that the major functionalities can be automated.

  • Develop Automation Framework − After building the POC, framework development is carried out, which is a crucial step for the success of any test automation project. Framework should be built after diligent analysis of the technology used by the application and also its key features.

  • Develop Test Script, Execute, and Analyze − Once Script development is completed, the scripts are executed, results are analyzed and defects are logged, if any. The Test Scripts are usually version controlled.

QTP - Environment SetUp

QTP is a commercial tool and the trial version can be downloaded from HP site directly. Only the current version, which is Unified functional testing (11.5x) is available for download. Following is the URL from where the trial version can be downloaded.

The Download URL − QTP

Installation Procedure

Step 1 − Click the "Trials and Demos" link and select "HP Unified Functional Testing 11.50 CC English SW E-Media Evaluation" as shown below −

Download and Install Step 1

Step 2 − After Selecting "HP Unified Functional Testing 11.50", the download wizard opens. Fill in the Personal details and click Next.

Download and Install Step 2

Step 3 − Read the ‘Terms of Use’ and click "NEXT".

Download and Install Step 3

Step 4 − The Download window opens. Now, click the "Download" button.

Download and Install Step 4

Step 5 − The downloaded file will be of the format .RAR. Now you need to unzip the archive and the folder contents would be as shown below and execute the Setup.exe.

Download and Install Step 5

Step 6 − Upon Executing the Setup File, in order to install, select "Unified Functional Testing Set up" from the list as shown below −

Download and Install Step 6

Step 7 − Then click Next to continue.

Download and Install Step 7

Step 8 − In the Custom Set up Window, select the plugins that are required for your automation i.e. you should select the plugins based on the technology of your application under test. For Example, if your application is based on .NET then you should ensure that you select .NET.

Download and Install Step 8

Step 9 − After selecting the required plugins for installation, click Next. After the completion of installation, you will end up with a Finish button Window.

Download and Install Step 10

Step 10 − Once you complete your installation, the "Additional Installation Requirements" Dialog box opens. Select everything in the list other than "Run License Installation Wizard" and click "RUN". We Need NOT select "Run License Installation Wizard" because we are installing the trial version, which, by default, gives a license for 30 days.

Download and Install Step 11

Step 11 − After the completion of Additional Installation Requirements, a tick mark is shown, which in turn states that the components are installed successfully. Now, click Close.

Download and Install Step 12

Launching UFT and Add ins Page

Step 1 − After Installation, application can be launched from the Start Menu as shown in the figure.

Download and Install Step 13

Step 2 − The license page appears. You can click Continue as we have installed the trial license.

Download and Install Step 14

Step 3 − The Add-ins dialog box opens for the user to select the required add-ins.

Note − Do not load all the add-ins but just the required add-ins and click OK.

Download and Install Step 15

Step 4 − After loading the required add-ins, the UFT 11.5 tool opens for the user and the first glimpse of the UFT looks, as shown below −

Download and Install Step 16

QTP - Record and Playback

Recording a test corresponds to recording the user actions of the application under test so that UFT automatically generates the scripts that can be played back. Record and Playback can give us the first impression of the tool, whether it can support the technology or not, if the initial settings are done correctly.

Steps for Record and Playback are as follows −

Step 1 − Click "New" test from the Start Page as shown below −

New Test Selection from Home Page

Step 2 − Clicking "New" Link, a new test window opens and the user needs to select the test type. Select "GUI Test", give a name for the test and the location where it needs to be saved.

Select Type of Test

Step 3 − Once a New test is created, the new test screen opens as shown below. Now, click the "Action1" tab, which is created with 1 action by default.

New Test Page

Step 4 − Click the "Record" Menu and select "Record and Run Settings" as shown below −

Record and Run Settings

Step 5 − The Record and Run Settings dialog box opens and based on the type of application, one can select Web, Java, or Windows Applications. For Example, here, we will record a Web Based Application (http://easycalculation.com/).

Record and Run Settings

Step 6 − Click Record. The Internet Explorer opens automatically with the web address https://www.easycalculation.com/ as per the settings. Click the "Numbers" link under "Algebra" and key in a number and hit "Calculate". After completion of the action, click the "Stop" button in the record panel. You will notice that the script is generated as shown below −

Generated Script

Step 7 − Now playback the script by clicking the playback button. The Script replays and the result is displayed.

Playback the Script

Step 8 − The result window is opened, by default, which exactly shows the timestamp of execution, pass and failed steps.

 Results Window Analysis

Significance of Record and Playback

  • It is used as the preliminary investigation method to verify if UFT can support the technology/application.

  • Used to create a test a basic functionality of an application or feature that does not require long-term maintenance.

  • It can be used for recording both mouse movements and keyboard inputs.

Modes of Recording

  • Normal Recording − This is the default Recording mode that records the objects and the operations performed on the application under test.

  • Analog Recording − This records not only the keyboard actions but also the mouse movements relative to the screen or the application window.

  • Low-Level Recording − This records the exact co-ordinates of the objects independent of the fact whether UFT recognizes the object or NOT. It just records the co-ordinates, hence does NOT record mouse movements.

  • Insight Recording − UFT records operations, based on its appearance and not based on its native properties.

How to Choose Recording Modes

After clicking the Recording button, the user can choose the recording mode from the recording pane that appears on the screen, once the recording starts. The selection can be made from any of the ones that has been discussed above.

Choosing Recording Modes

You will see that the following scenario is recorded in all the modes and the same action has been recorded under various circumstances.

  • Launch IE - https://www.easycalculation.com/
  • Click "Numbers" under "Algebra"
  • Click "Square Root" link
  • Enter a value to calculate the square root. Let us say 10
  • Hit Calculate

Script Recorded under Default, Analog and Low Level recording mode is given below −

' DEFAULT RECORDING MODE 
Browser("Free Online Math Calculator").Page("Free Online Math 
Calculator").Link("Numbers").Click 

Browser("Free Online Math Calculator").Page("Numbers Calculator - 
Math").Link("Square Root").Click 

Browser("Free Online Math Calculator").Page("Square Root 
Calculator").WebEdit("n").Set "10" 

Browser("Free Online Math Calculator").Page("Square Root 
Calculator").WebButton("calculate").Click 

' ANALOG RECORDING MODE 
Desktop.RunAnalog "Track1" 

' LOW LEVEL RECORDING MODE 
Window("Windows Internet Explorer").WinObject("Internet Explorer_Server").Click 
235,395 

Window("Windows Internet Explorer").WinObject("Internet Explorer_Server").Click 
509,391 

Window("Windows Internet Explorer").WinObject("Internet Explorer_Server").Click 
780,631 

Window("Windows Internet Explorer").WinObject("Internet Explorer_Server").Type 
"10" 

Window("Windows Internet Explorer").WinObject("Internet Explorer_Server").Click 
757,666

The recordings using insight recording mode will be as shown below −

Insight Recording Modes

QTP - Object Repository

Object Repository

Object Repository is a collection of object and properties with which QTP will be able to recognize the objects and act on it. When a user records a test, the objects and its properties are captured by default. Without understanding objects and its properties, QTP will NOT be able to play back the scripts.

Click on each one of the following topics to know more about Object Repository and its associated features.

Sr.No. Topic & Description
1 Object Spy and its Features

To understand the usage of object spy and its associated functionalities.

2 Working with Object Repository

Adding, editing, deleting objects from an Object Repository and its associated functionalities.

3 Types of Object Repository

Deals with shared Object and local Object Repository and their context with respect to scripting.

4 User-defined Objects

Deals with the circumstances to use the User-Defined Objects.

5 Object Repository in XML

Deals with converting OR's to XML and using the object Repository as XML.

6 Comparing and Merging OR

Operations such as Compare OR', Merge OR's to effectively work with Object Repository.

7 Ordinal Identifiers

Circumstances where the ordinal identifiers are used and its advantages.

8 Child Objects

Using Child Objects for effective scripting

QTP - Actions

Actions helps testers to divide scripts into groups of QTP statements. Actions are similar to functions in VBScript; however, there are a few differences. By default, QTP creates a test with one action.

Actions Functions
Action is an in-built feature of QTP. VBScript Functions are supported by both VBScript and QTP.
Actions parameters are passed by value only. Function parameters are passed either by by value or by ref.
Actions have extension .mts Functions are saved as .vbs or .qfl
Actions may or may not be reusable. Functions are always reusable.

The properties of the action can be accessed by right clicking on the Script Editor Window and selecting "Properties".

Action Properties

Action properties contains the following information −

  • Action Name
  • Location
  • Reusable Flag
  • Input Parameters
  • Output Parameters

Types of Actions

There are three types of actions −

  • Non-reusable action − An action that can be called only in that specific test in which it has been designed and can be called only once.

  • Reusable action − An action that can be called multiple times, any test in which it resides, and can also be used by any other tests.

  • External Reusable action − It is a reusable action stored in another test. External actions are read-only in the calling test, but it can be used locally with the editable copy of the Data Table information for the external action.

Working with Actions

There are three options to insert an action. Click on each one of those to know more about the selected type of action.

Sr.No. Action Type & Description
1 Insert Call to New Action

Inserts a New Action from the existing action

2 Insert Call to Copy of Action

Inserts a copy of an existing action

3 Insert Call to Existing Action

Inserts a call to existing re-usable action

QTP - Datatables

A DataTable, similar to Microsoft Excel, helps the testers to create data-driven test cases that can be used to run an Action multiple times. There are two types of Datatables −

  • Local DataTable − Each action has its own private datatable, also known as local datatable, which is can also be accessed across actions.

  • Global DataTable − Each test has one global data sheet that is accessible across actions.

The data sheet can be accessed from the "Data" Tab of QTP as shown below −

Data Table in QTP

To execute a test case for some specified number of iterations, one can set the iterations of global datatable in the Test Settings dialog, that can be accessed using File → Settings → Run(Tab) as shown below −

Data Table in QTP

Example

For example, if a user wants to parameterize "compound Interest" of http://easycalculation.com/ that can be accessed using http://easycalculation.com/compound-interest.php. The Parameters can be created as shown below. Most of the functionalities of Excel can be used in Data table as well.

Data Table in QTP

DataTable Operations

There are three types of objects to access DataTable. DataTable operations can be well understood by traversing through the following −

Sr.No. Object Type & Description
1 Data Table Methods

Gives detailed information about the data table methods.

2 DTParameter Object Methods

Gives detailed information about the DTParameter methods.

3 DTSheet Object Methods

Gives detailed information about the DTSheet methods.

QTP - CheckPoints

Checkpoints, as the name says it all, refer to a validation point that compares the current value of specified properties or current state of an object with the expected value, which can be inserted at any point of time in the script.

Types of Checkpoints

Sr.No. Type & Description
1

Standard Checkpoint

Verifies the property values of an object in application under test and supported by all add-in environments.

2

Bitmap Checkpoint

Verifies an area of your application as a bitmap

3

File Content Checkpoint

Verifies the text in a dynamically generated or accessed file such as .txt,.pdf

4

Table Checkpoint

Verifies the information within a table. Not all environments are supported.

5

Text Checkpoint

Verify if the text that is displayed within a defined area in a Windows-based application, according to specified criteria.

6

Text Area Checkpoint

Verifies if the text string is displayed within a defined area in a Windows-based application, according to specified criteria.

7

Accessibility Checkpoint

Verifies the page and reports the areas of the Web site that may not conform to the World Wide Web Consortium (W3C) Web Content Accessibility Guidelines

8

Page Checkpoint

Verifies the characteristics of a Web page. It can also check for broken links.

9

Database Checkpoint

Verifies the contents of a database accessed by the application under test.

10

XML Checkpoint

Verifies the content of the .xml documents or .xml documents in Web pages and frames.

Inserting CheckPoint

When the user wants to insert a checkpoint, one has to ensure that most of the checkpoints are supported during the recording sessions only. Once the user stops recording, checkpoints are not enabled.

Given below is the checkpoint menu, when the user is NOT in the recording mode.

Check Point Menu when Recording NOT in Progress

Given below is the checkpoint menu, when the user is in the recording mode.

Check Point Menu when Recording is in Progress

Example

The checkpoints are added for the application under test - "http://easycalculation.com/"

' 1. Inserted Standard Checkpoint
Status = Browser("Math Calculator").Page("Math 
   Calculator").Link("Numbers").Check CheckPoint("Numbers")

If Status Then
   print "Checkpoint Passed"
Else
   Print "Checkpoint Failed"
End if

' 2. Inserted BitMap Checkpoint
imgchkpoint = Browser("Math Calculator").Page("Math 
   Calculator").Image("French").Check CheckPoint("French")

If imgchkpoint Then
   print "Checkpoint Passed"
Else
   Print "Checkpoint Failed"
End if

Viewing Checkpoint Properties

After inserting, in case a tester want to change the values, we can do so by right clicking on the keyword 'checkpoint' of the script and navigating to "Checkpoint Properties" as shown below −

Check point properties.

You can locate the same checkpoints in object repository, as well, as shown below. It exactly shows what type of checkpoint is used and what are the expected values, and time out values.

Check point properties.

QTP - Synchronization

Synchronization point is the time interface between Tool and Application under test. Synchronization point is a feature to specify the delay time between two steps of the test script.

For example, clicking on a link may load the page is 1 second, sometimes 5 seconds or even it may take 10 seconds to load it completely. It depends on various factors such as the application-server response time, network bandwidth, and client system capabilities.

If the time is varying then the script will fail, unless the tester handles these time differences intelligently.

Ways to Insert Sync Point

  • WaitProperty
  • Exist
  • Wait
  • Sync(only for web based apps)
  • Inserting QTP Inbuilt Synchronization points.

Let us say, we need to insert a sync point between clicking on "numbers" link and clicking on "simple Interest" calculator in "www.easycalculation.com". We will now take a look at all the five ways to insert sync point for the above scenario.

Method 1 − WaitProperty

WaitProperty is a method that takes the property name, Value and Timeout value as input to perform the sync. It is a dynamic wait and hence, this option is encouraged.

' Method 1 - WaitProperty with 25 seconds
Dim obj
Set obj = Browser("Math Calculator").Page("Math Calculator")
obj.Link("Numbers").Click

obj.Link("Simple Interest").WaitProperty "text", "Simple Interest",25000
obj.Link("Simple Interest").Click

Method 2 − Exist

Exist is a method that takes the Timeout value as input to perform the sync. Again, it is a dynamic wait and hence this option is encouraged.

' Method 2 : Exist Timeout - 30 Seconds
Dim obj
Set obj = Browser("Math Calculator").Page("Math Calculator")
obj.Link("Numbers").Click

If obj.Link("Simple Interest").Exist(30) Then
   obj.Link("Simple Interest").Click

Else
   Print "Link NOT Available"
End IF

Method 3 − Wait

Wait is a hardcoded sync point, which waits independent of the event happened or NOT. Hence, usage of Wait is discouraged and can be used for shorter wait time such as 1 or 2 seconds.

' Method 3 : Wait Timeout - 30 Seconds
Dim obj
Set obj = Browser("Math Calculator").Page("Math Calculator")
obj.Link("Numbers").Click
wait(30)
Browser("Math Calculator").Page("Math Calculator").Link("Simple Interest").Click

Method 4 − Sync Method

Sync Method can be used only for web applications where there is always a lag between page loads.

' Method 4 : 
Dim obj
Set obj = Browser("Math Calculator").Page("Math Calculator")
obj.Link("Numbers").Click

Browser("Math Calculator").Sync
Browser("Math Calculator").Page("Math Calculator").Link("Simple Interest").Click

Method 5 − Inserting QTP Inbuilt Synchronization points

Step 1 − Get into Recording Mode. This option would be disabled if the user is NOT in Recording Mode.

Step 2 − Go to "Design" → "Synchronization Point".

Step 3 − We need to select the object, which we want to be the Sync Point. After selecting the object, object window opens as shown below −

QTP Sync Point

Step 4 − Click OK; the "Add Synchronization Window" opens. Select the Property, Value and Time out value and click OK as shown below −

QTP Sync Point

Step 5 − The script would be generated as shown below, which is the same as that of the WaitProperty(Method 1) that we had already discussed −

Browser("Math Calculator").Page("Math Calculator").Link("Numbers").Click

Browser("Math Calculator").Page("Math Calculator").Link("Simple 
   Interest").WaitProperty "text", "Simple Interest", 10000

Default Synchronization

When the user has not used any of the above sync methods, still QTP has an in-built Object synchronization timeout which can be adjusted by the user.

Navigate to "File" >> "Settings" >> Run Tab >> Object Synchronization Time out as shown below.

Default Synchronization Time Out

QTP - Smart Identification

Sometimes, QTP is unable to find any object that matches the recognized object description or it may find more than one object that fits the description, then QTP ignores the recognized description and uses the Smart Identification mechanism to recognize the object.

QTP's Smart Identification uses two types of properties −

  • Base Filter Properties − The basic properties of a particular test object class whose values cannot be changed without changing the essence of the original object.

  • Optional Filter Properties − Other properties also assist in identifying the objects of a particular class whose properties are unlikely to change often but can be ignored if they are no longer applicable.

Enabling Smart Identification for an Object

Step 1 − Navigate to "Tools" → "Object Identification". Object Identification dialog opens.

Step 2 − Choose the Environment, Object Class and Turn ON "Enable Smart Identification" as shown below −

Smart Identification Configuration

Step 3 − Click Configure and choose the base and Optional Filter Properties.

Smart Identification Configuration

Step 4 − Add Properties in Base Properties apart from the default one and also add/remove Optional Filter Properties. Please note that same properties cannot be a part of both Mandatory and Assistive Properties and click "OK".

Smart Identification Configuration

Step 5 − Verify if the Smart Identification is enabled after adding object of that type in the Object Repository. Smart Identification is set to TRUE. We can also make it False in case we do not want to enable Smart Identification.

Smart Identification Configuration

Step 6 − We can even disable a test Level by applying at test script level under "Settings" of "File" Menu as shown below −

Smart Identification Configuration

Step 7 − If the Smart Identification is disabled as per Step# 6 then it will not apply smart identification for any object during the script execution.

Step 8 − In case the objects are added with Smart Identification as Off, QTP will not use Smart Identification for recognizing in future, even though we have enabled it later.

QTP - Debugging

Debugging, in automation testing context, is a systematic process of spotting and fixing the coding issues in the automation script so that the script will be more robust and can spot the defects in the application.

There are various ways to perform debugging using break points in QTP. Break points can be inserted just by pressing "F9" or by using the Menu option "Run" → "Inserting/Removing Break Point".

After Inserting the Break point, the "Red Colored" Dot and the line will be highlighted in RED as shown below −

Debugging using Break Point

Method ShortCut Description
Step Into F11 Used to execute each and every Step. Steps into the Function/Action and executes line by line. It pauses on each line after execution.
Step Over F10 Used to Step over the Function. Step Over runs only the current step in the active document.
Step Out Shift+F11 After Step Into the function, you can use the Step Out command. Step Out continues the run to the end of the function and then pauses the run session at the next line.

Options in Break Point

Various Options in Break Point can be accessed by Navigating through the 'Run' Menu.

Sr.No. ShortCut & Description
1

F9

Insert/Remove BreakPoint

2

Ctrl+F9

Enable/Disable BreakPoint

3

Ctrl+Shift+F9

Clear All BreakPoint

4

Use Only Menu

Enable/Disable All BreakPoints

Debugging Pane

The following are the panes in the debugging window −

Debugging using Break Point
  • Output − This Tab displays all the Output of the Print Statements.

  • Watch − This Tab displays the Boolean output of the Given Expression.

  • LocalVariables − This Tab displays the Output of the Local Variables.

Example

The Watch Pane shows the output expression as shown below −

Debugging using Break Point

The Local Variables Pane shows the values held by the local variables as shown below −

Debugging using Break Point

QTP - Error Handling

There are various ways of handling errors in QTP. There are three possible types of errors, one would encounter, while working with QTP. They are −

  • Syntax Errors
  • Logical Errors
  • Run Time Errors

Error Types

Syntax Errors

Syntax errors are the typos or a piece of the code that does not confirm with the VBscripting language grammar. Syntax errors occur at the time of compilation of code and cannot be executed until the errors are fixed.

To verify the syntax, use the keyboard shortcut Ctrl+F7 and the result is displayed as shown below. If the window is not displayed one can navigate to "View" → "Errors".

Error Handling

Logical Errors

If the script is syntactically correct but it produces unexpected results, then it is known as a Logical error. Logical error usually does not interrupt the execution but produces incorrect results. Logical errors could occur due to variety of reasons, viz- wrong assumptions or misunderstandings of the requirement and sometimes incorrect program logics (using do-while instead of do-Until) or Infinite Loops.

One of the ways to detect a logical error is to perform peer reviews and also verify the QTP output file/result file to ensure that the tool has performed the way it was supposed to do.

RunTime Errors

As the name states, this kind of error happens during Run Time. The reason for such kind of errors is that the script trying to perform something is unable to do so and the script usually stops, as it is unable to continue with the execution. Classic examples for Run Time Errors are −

  • File NOT found but the script trying to read the file
  • Object NOT found but the script is trying to act on that particular object
  • Dividing a number by Zero
  • Array Index out of bounds while accessing array elements

Handling Run-Time Errors

There are various ways to handle errors in the code.

1. Using Test Settings − Error handling can be defined the Test Settings by Navigating to "File" >> "Settings" >> "Run" Tab as shown below. We can select any of the specified settings and click "OK".

Error Handling

2. Using On Error Statement − The ‘On Error’ statement is used to notify the VBScript engine of intentions to handle the run-time errors by a tester, rather than allowing the VBScript engine to display error messages that are not user-friendly.

  • On Error Resume Next − On Error Resume Next informs the VBScript engine to process executing the next line of code when an error is encountered.

  • On error Goto 0 − This helps the testers to turn off the error handling.

3. Using Err Object − Error object is an in-built object within VBScript that captures the run-time error number and error description with which we are able to debug the code easily.

  • Err.Number − The Number property returns or sets a numeric value specifying an error. If Err.Number value is 0 then No error has occurred.

  • Err.Description − The Description property returns or sets a brief description about an error.

  • Err.Clear − The Clear method resets the Err object and clears all the previous values associated with it.

Example

'Call  the function to Add two Numbers Call Addition(num1,num2) 

Function Addition(a,b)  
   On error resume next  
      If NOT IsNumeric(a) or IsNumeric(b) Then 
         Print "Error number is  " &  err.number & " and description is : 
            " &  err.description 
         Err.Clear 
         Exit Function 
      End If 
   Addition = a+b 

   'disables error handling  
   On Error Goto 0 
End function 

4. Using Exit Statement − Exit Statements can be used along with Err object to exit from a test or action or iteration based on the Err.Number value. Let us see each one of those Exit statements in detail.

  • ExitTest − Exits from the entire QTP test, no matter what the run-time iteration settings are.

  • ExitAction − Exits the current action.

  • ExitActionIteration − Exits the current iteration of the action.

  • ExitTestIteration − Exits the current iteration of the QTP test and proceeds to the next iteration.

5. Recovery Scenarios − Upon encountering an error, recovery scenarios are triggered based on certain conditions and it is dealt in detail in a separate chapter.

6. Reporter Object − Reporter Object helps us to report an event to the run results. It helps us to identify if the concerned action/step is pass/fail.

'Syntax: Reporter.ReportEventEventStatus, ReportStepName, Details, 
[ImageFilePath] 

'Example 
Reporter.ReportEvent micFail, "Login", "User is unable to Login."  

QTP - Recovery Scenarios

Recovery Scenarios

While executing the QTP scripts, we might get some unexpected errors. In order to recover the tests and continue executing the rest of the script from these unexpected errors, Recovery Scenarios are used. The Recovery Scenario Manager can be accessed by Navigating to "Resources" → Recovery Scenario Manager as shown below −

Recovery Scenario Manager Access

Steps to Create Recovery Scenario

Step 1 − Click "New" Recovery Scenario button; the Recovery Scenario Wizard opens as shown below −

Recovery Scenario Manager - Access

Step 2 − Choose the Trigger Event. It corresponds to event, which can arise in any of the following four events −

  • Pop-Up Window
  • Object State
  • Test Run Error
  • Application Crash

Step 3 − The Recovery Operations Window opens. Recovery Operation can perform any of the following Operation as shown in the screenshot below −

Recovery Scenario Manager Access

Step 4 − After specifying the appropriate Recovery Operation, we need to specify the Post Recovery Operation as well, as shown below −

Recovery Scenario Manager Access

Step 5 − After specifying the Post Recovery Operation, the recovery scenario should be named and added to the Test so that it can be activated.

Recovery Scenario Manager Access

Step 6 − The Recovery Scenario creation is complete and needs to be mapped to the current Test by checking the option "Add Scenario to the current Test" and click "Finish".

Recovery Scenario Manager Access

Step 7 − The Added Recovery Scenario will be as shown below and click the "Close" Button to continue.

Recovery Scenario Manager Access

Step 8 − After clicking the Close button, QTP would prompt the user to save the created Recovery scenario. It will be saved with the extension .qrs and the wizard would close.

Recovery Scenario Manager Access

Verification

The Created Recovery Scenario should be a part of the test now and can be verified by navigating to "File" → "Settings" → "Recovery" Tab.

Recovery Scenario Manager Access

QTP - Environment Variables

QTP environment variables are special types of variables that can be accessed by all actions, function libraries, and recovery scenarios. There are in-built environment variables for Windows that are available to all the applications running on that particular system, but QTP environment variables are only available to that particular test script during run-time.

Types of Environment Variables

Built-in Environment Variables − provides a range of environment parameters that can provide information such as test name, action name, the test path, local host name, the operating system name, type and its version. The Environment Variable names can be accessed by navigating to "File" → "Test Settings" → "Environment" Tab.

Build-in Environment Variables

User defined Internal − User defined variables can be saved by selecting "User Defined" in the Environment Tab Window. The "+" button is clicked to enter Parameter Name and Value as shown below −

User Defined Internal Environment Variables

User Defined External − User Defined Variables can be stored in an external file as a .xml file and can be loaded into the test as shown in the figure given below. It can also be loaded dynamically during run-time as explained below in one of the examples.

User Defined Internal Environment Variables

Environment Variables – Supported Methods

1. ExternalFileName Property − Returns the name of the loaded external environment variable file specified in the Environment tab of the Test Settings dialog box. If no external environment variable file is loaded, this property returns an empty string.

x = Environment.ExternalFileName 
print x

User Defined Internal Environment Variables

2. LoadFromFile Method − Loads the specified environment variable file (.xml) dynamically during run time. When using this method, the environment variables need not be added manually into the Environment Tab.

Environment.LoadFromFile "D:\config.xml"
b = Environment.Value("Browser")
print b

User Defined Internal Environment Variables

3. Value Property − Retrieves the value of environment variables. We can also set the value of user-defined internal environment variables using this property.

' Get the Value of the InBuilt Environment Variables
a = Environment.Value("OS")
print a
b = Environment.Value("ActionName")
print b
  
'Loaded from External File
Environment.LoadFromFile "D:\config.xml"
c = Environment.Value("Browser")
print c
User Defined Internal Environment Variables

QTP - Library Files

In order to modularize the script, library files are added to the QTP Script. It contains variable declaration, Functions, Classes etc. They enable reusability that can be shared across test scripts. They are saved with an extenstion .vbs or .qfl

A new Library file can be created by navigating to "File" >> "Function Library".

Associating Function Libraries

Method 1 − By using "File" > "Settings" > Resources > Associate Function Library option. Click the "+" button to add Function Library file and add it using the actual path or relative path as shown below −

Associating Library File

Method 2 − Using ExecuteFile method.

'Syntax : ExecuteFile(Filepath)
ExecuteFile "C:\lib1.vbs" 
ExecuteFile "C:\lib2.vbs" 

Method 3 − Using LoadFunctionLibrary Method.

'Syntax : LoadFunctionLibrary(Filepath)
LoadFunctionLibrary "C:\lib1.vbs" 
LoadFunctionLibrary "C:\lib2.vbs" 

Method 4 − Automation Object Model(AOM) - It is a mechanism, using which, we can control various QTP operations outside QTP. Using AOM, we can launch QTP, Open the Test, Associate Function Libraries etc. The following VbScript should be saved with Extension .vbs and upon executing the same, QTP will be launched and test would start executing. AOM will be discussed in detail in the later chapters.

'Launch QTP
Set objQTP = CreateObject("QuickTest.Application")
objQTP.Launch
objQTP.Visible = True
  
'Open the test
objQTP.Open "D:\GUITest2", False, False
Set objLib = objQTP.Test.Settings.Resources.Libraries
  
'Associate Function Library if NOT associated already.
If objLib.Find("C:\lib1.vbs") = -1 Then 
  objLib.Add "C:\lib1.vbs", 1 
End

QTP - Automated Testing Results

Test Results

The Test Results Window gives us sufficient information to show the steps passed, failed etc. Results window opens automatically after the execution of the test (as per default settings). The following information is displayed −

  • Steps Passed
  • Steps Failed
  • Environment Parameters
  • Graphical Statistics
Test Results

Operations performed in Test Results

Converting Results to HTML

In the Results Viewer window, navigate to "File" → "Export to File". Export Run Results dialog box opens as shown below −

Test Results

We can choose what type of report is to be exported. It can be short results, detailed results or even, we can select nodes. After selecting the File Name and exporting it, the file is saved as .HTML File

Filtering the Results

Results can be filtered based on Status, Node Type, and Iterations. It can be accessed by using the Filter button in the "Test Results Window".

Test Results

Raising Defects

Defects can be logged into QC directly from the Test Results Window pane by accessing "Tools" → "Add Defect" which open's the connection to ALM as shown below −

Test Results

Test Results

The Automatic Test Results Window can be configured under "Tools" → "Options" → "Run Sessions" Tab. We can turn it OFF, if required, and also, we can switch ON "Automatically Export Results when session Ends".

Test Results

The screenshot or the movie can be recorded based on the settings. The same can be configured under "Tools" → "Options" → "Screen Capture" Tab. We can save the screenshot or movies based on the following three conditions −

  • For Errors
  • Always
  • For Errors and Warnings
Test Results

QTP - Working with GUI Objects

There are various GUI objects, with which QTP interacts, during the script execution. Hence, it is important to know the basic methods for the key GUI objects using which we will be able to work on it effectively.

Working with Text Box

Following are the methods using which we access text box during Run Time −

  • Set − Helps the tester to Set Values into the Text Box

  • Click − Clicks on the Text Box

  • SetSecure − Used to set the text in the password boxes securely

  • WaitProperty − Waits Till the Property value becomes true

  • Exist − Checks for the existence of the Text Box

  • GetROProperty("text") − Gets the Value of the Text Box

  • GetROProperty("Visible") − Returns a Boolean value if visible

Example

Browser("Math Calculator").Sync
Set Obj = Browser("Math Calculator").Page("SQR Calc").WebEdit("n")

'Clicks on the Text Box
Obj.Click

'Verify if the Object Exist - Returns Boolean value
a = obj.Exist
print a

'Set the value
obj.Set "10000" : wait(2)

'Get the Runtime Object Property - Value of the Text Box
val = obj.GetROProperty("value")
print val

'Get the Run Time Object Property - Visiblility - Returns Boolean Value
x = Obj.GetROProperty("visible")
print x

Working with Check Box

Following are some of the key methods with which one can work with Check Box −

  • Set − Helps the tester to Set the checkbox value "ON" or "OFF"

  • Click − Clicks on the check Box. Even checks ON or OFF but user will not be sure about the status

  • WaitProperty − Waits Till the Property value becomes true

  • Exist − Checks for the existence of the Check Box

  • GetROProperty("name") − Gets the Name of the check Box

  • GetROProperty("Visible") − Returns a Boolean value if visible

Example

'To Check the Check Box
Set Obj = Browser("Calculator").Page("Gmail").WebCheckBox("PersistentCookie")
Obj.Set "ON"

'To UnCheck the Check Box
Obj.Set "OFF"

'Verifies the Existance of the Check box and returns Boolean Value
val = Obj.Exist
print val

'Fetches the Name of the CheckBox
a = Obj.GetROProperty("name")
print a

'Verifies the visible property and returns the boolean value.
x = Obj.GetROProperty("visible")
print x

Working with Radio Button

Following are some of the key methods with which one can work with Radio Button −

  • Select(RadioButtonName) − Helps the tester to Set the Radio Box "ON"

  • Click − Clicks on the Radio Button. Even Radio Button ON or OFF but tester cannot get the status

  • WaitProperty − Waits Till the Property value becomes true

  • Exist − Checks for the existence of the Radio Button

  • GetROProperty("name") − Gets the Name of the Radio Button

  • GetROProperty("Visible") − Returns a Boolean value if visible

Example

'Select the Radio Button by name "YES"
Set Obj = Browser("Calculator").Page("Forms").WebRadioGroup("group1")
Obj.Select("Yes")

'Verifies the Existance of the Radio Button and returns Boolean Value
val = Obj.Exist
print val

'Returns the Outerhtml of the Radio Button
txt = Obj.GetROProperty("outerhtml")
print text

'Returns the boolean value if Radio button is Visible.
vis = Obj.GetROProperty("visible")
print vis

Working with Combo Box

Following are some of the key methods with which one can work with Combo Box −

  • Select(Value) − Helps the tester to Select the value from the ComboBox

  • Click − Clicks on the object

  • WaitProperty − Waits Till the Property value becomes true

  • Exist − Checks for the existence of the Combo Box

  • GetROProperty("Text") − Gets the Selected Value of the Combo Box

  • GetROProperty("all items") − Returns all the items in the combo Box

  • GetROProperty("items count") − Returns the number of items in the combo Box

Example

'Get the List of all the Items from the ComboBox
Set ObjList = Browser("Math Calculator").Page("Statistics").WebList("class")
x = ObjList.GetROProperty("all items")
print x

'Get the Number of Items from the Combo Box
y = ObjList.GetROProperty("items count")
print y

'Get the text value of the Selected Item
z = ObjList.GetROProperty("text")
print z

Working with Buttons

Following are some of the key methods with which one can work with Buttons −

  • Click − Clicks on the Button

  • WaitProperty − Waits Till the Property value becomes true

  • Exist − Checks for the existence of the Button

  • GetROProperty("Name") − Gets the Name of the Button

  • GetROProperty("Disabled") − Returns a Boolean value if enabled/disabled

Example

'To Perform a Click on the Button
Set obj_Button = Browser("Math Calculator").Page("SQR").WebButton("Calc")
obj_Button.Click

'To Perform a Middle Click on the Button
obj_Button.MiddleClick

'To check if the button is enabled or disabled.Returns Boolean Value
x = obj_Button.GetROProperty("disabled")
print x

'To fetch the Name of the Button
y = obj_Button.GetROProperty("name")
print y

Working with webTables

In Today's web based application, webTables have become very common and testers need to understand how WebTables work and how to perform an action on webTables. This topic will help you to work with the webTables effectively.

Sr.No. Statement & Description
1

if statement

An if statement consists of a boolean expression followed by one or more statements.

2

if...else statement

An if else statement consists of a boolean expression followed by one or more statements. If the condition is True. The statements under if statements are execued. If the condition is false. Else part of the script is Executed

3

if..elseif...else statement

An if statement followed by one or more Elseif statements, that consists of boolean expressions and then followed by an optional else statement, which executes when all the condition becomes false.

4

nested if statements

An if or elseif statement inside another if or elseif statement(s).

5

switch statement

A switch statement allows a variable to be tested for equally aganist a list of values.

  • html id − If the table has an id tag then it is best to make use of this property.

  • innerText − Heading of the Table.

  • sourceIndex − Fetches the Source Index of the Table

  • ChildItemCount − Gets the number of ChildItems present in specified Row

  • RowCount − Gets the number of Rows in the Table

  • ColumnCount − Gets the number of Columns in the Table

  • GetcellData − Gets the Value of the Cell based on the column and Row Index

Example

Browser("Tutorials Point").Sync
' WebTable 
Obj = Browser("Tutorials Point").Page("VBScript Decisions").WebTable("Statement")
' Fetch RowCount
x = Obj.RowCount
print x

' Fetch ColumnCount
y = Obj.ColumnCount(1)
print y

' Print the Cell Data of the Table
For i = 1 To x Step 1
   
   For j = 1 To y Step 1
      z = Obj.GetCellData(i,j)
      print "Row ID : " & i & " Column ID : " & j & " Value : " & z
   Next
Next

'Fetch the Child Item count of Type Link in a particular Cell
z = Obj.ChildItemCount(2,1,"Link")
print z

QTP - Virtual Objects

What are Virtual Objects?

Sometimes, an application under test may contain standard window object but are not recognized by QTP. Under these circumstances, objects can be defined as virtual object(VO) of type button, link etc. so that user actions can be simulated on the virtual objects during execution.

Example

Let us say we are automating a scenario in Microsoft Word. I activated MS word application and I click on any icon in the ribbon. For example, on the Ribbon, Insert tab is clicked and then the user clicks the "Picture" button. A button is recognized as WinObject; hence, importance of virtual objects is pronounced.

Window("Microsoft Word").WinObject("Ribbon").Click 145,45
Window("Microsoft Word").WinObject("Ribbon").WinObject("Picture...").Click 
170,104

Creating a Virtual Object

Step 1 − In such scenarios, virtual Objects are created using Virtual Object Manager or New Virtual Object from "Tools" >> "Virtual Object" >> "New Virtual Object" and click the "Next" button.

Virtual Object Step 1

Step 2 − Map the Object against the Class Type and click "Next".

Virtual Object Step 2

Step 3 − Click "Mark Object" Button. A cross hair cursor would appear and mark the object that you would like to map and click "Next".

Virtual Object Step 3

Step 4 − Select the parent of the Virtual object and click "Next".

Virtual Object Step 4

Step 5 − Name the collection in which you would like to store the virtual object and click "Finish".

Virtual Object Step 5

Virtual Object Manager

Virtual object Manager manages the collections of Virtual objects. Testers can add or Delete the Virtual Objects from the Virtual Object manager.

Navigation to Virtual object Manager : "Tools" >> "Virtual Object Manager" as shown below −

Virtual Object Step 6

Using Virtual Objects

After creating the Virtual Objects, the created object can be used as shown below −

Window("Microsoft Word").WinObject("Ribbon").VirtualButton("button").Click

Virtual Object Limitations

  • QTP does not support virtual objects for analog or low-level recording.

  • Checkpoints cannot be added on Virtual Objects.

  • Virtual Objects are not controlled by Object Repository.

  • Though we map an object to a particular class (button or List), all the methods of the native objects are not supported by Virtual objects.

  • Object Spy cannot be used on Virtual Object.

  • The test execution will fail if the screen resolution changes as the co-ordinates change.

  • Application Window should be of same screen size so that Virtual objects are captured correctly.

QTP - Accessing Databases

As such, QTP does not provide any built-in support to connect to database, however using VBScript testers will be able to connect and interact with databases using ADODB objects.

ADODB has 4 properties or methods with which we will be able to work with the databases. They are −

  • ADODB.Connection − Used to establish a connection to the Database

  • ADODB.Command − Used to execute a SQL command(Queries or Stored Procedures)

  • ADODB.Fields − Used to fetch a particular column from a record set after executing a query/stored proc

  • ADODB.Recordset − Used to fetch data from a database

How to connect to Database?

Databases can be connected using Connection strings. Each database differs in the way we connect to them. However, the connection strings can be built with the help of www.connectionstrings.com

Let us see how to connect to the database with the following parameters −

  • Database Type − MSSQL SERVER

  • Server Name − SQLEXPRESS

  • Database Name − Trial

  • User Id − sa

  • password − Password123

The output of the Query is shown in the SQL Server Management Studio as follows −

Accessing Database

Dim objConnection 
'Set Adodb Connection Object
Set objConnection = CreateObject("ADODB.Connection")     
Dim objRecordSet 
 
'Create RecordSet Object
Set objRecordSet = CreateObject("ADODB.Recordset")     
 
Dim DBQuery 'Query to be Executed
DBQuery = "Select NAME from dbo.EMPLOYEE where AGE = 29"
 
'Connecting using SQL OLEDB Driver
objConnection.Open "Provider = sqloledb.1;Server =.\SQLEXPRESS;
User Id = sa;Password=Password123;Database = Trial"
 
'Execute the Query
objRecordSet.Open DBQuery,objConnection
 
'Return the Result Set
Value = objRecordSet.fields.item(0)				
msgbox Value
 
' Release the Resources
objRecordSet.Close        
objConnection.Close		
 
Set objConnection = Nothing
Set objRecordSet = Nothing

Result

On executing the above script, the output is shown in the message box as shown below −

Accessing Database 2

QTP Working with XML

XML is a markup language designed to store data in a format that can be both readable by human and machine. Using XML, data can also be easily exchanged between computer and database systems.

Sample XML and their key elements are represented below −

Working with XML

Accessing XML

Const XMLDataFile = "C:\TestData.xml"
Set xmlDoc = CreateObject("Microsoft.XMLDOM")
xmlDoc.Async = False
xmlDoc.Load(XMLDataFile)

' Getting the number of Nodes (books)
Set nodes = xmlDoc.SelectNodes("/bookstore/book")
Print "Total books: " & nodes.Length    ' Displays 2

' get all titles
Set nodes = xmlDoc.SelectNodes("/Booklib/book/value/text()")

' get their values
For i = 0 To (nodes.Length - 1)
   Title = nodes(i).NodeValue
   Print "Title is" & (i + 1) & ": " & Title
Next

Comparing XML

We can compare two given XMLs −

Dim xmlDoc1
Dim xmlDoc2

' Load the XML Files
Set xmlDoc1 = XMLUtil.CreateXMLFromFile ("C:\File1.xml")
Set xmlDoc2 = XMLUtil.CreateXMLFromFile ("C:\File2.xml")

'Use the compare method of the XML to check if they are equivalent
Comp = xmlDoc1.Compare (xmlDoc1, xmlDoc2)

'Returns 1 if the two files are the same
If Comp = 1 Then
   Msgbox "XML Files are the Same"
Else
   Msgbox "XML Files are Different"
End if

QTP - Descriptive Programming

QTP scripts can execute only if the objects are present in the Object Repository. The descriptions of the Objects are created using Descriptive programming −

  • When the testers want to perform an operation on an object that is not present in the object repository

  • When objects in the application are very dynamic in nature.

  • When the Object Repository grows big, it results in poor Performance as the size of the Object Repository increases.

  • When the framework is built, such that it has been decided not to use Object Repository at all.

  • When testers want to perform an action on the application at run-time without having the knowledge of object's unique properties.

Syntax

There are two ways to scripting using Descriptive Programming technique. They are −

  • Description Objects
  • Description Strings

Description Objects

Script is developed using Description Objects that depend upon the properties used and their corresponding values. Then, these descriptions are used to build the script.

'Creating a description object
Set btncalc = Description.Create()

'Add descriptions and properties
btncalc("type").value = "Button"
btncalc("name").value = "calculate"
btncalc("html tag").value = "INPUT"

' Use the same to script it
Browser("Math Calc").Page("Num Calculator").WebButton(btncalc).Click

Description Strings

The description of the objects is developed using the properties and values as strings as shown below.

Browser("Math Calc").Page("Num Calculator").WebButton("html 
tag:=INPUT","type:=Button","name:=calculate").Click

Child Objects

QTP provides the ChildObjects method, which enables us to create a collection of objects. The parent objects precedes ChildObjects.

Dim oDesc
Set oDesc = Description.Create
oDesc("micclass").value = "Link"

'Find all the Links
Set obj = Browser("Math Calc").Page("Math Calc").ChildObjects(oDesc)

Dim i
'obj.Count value has the number of links in the page

For i = 0 to obj.Count - 1	 
   'get the name of all the links in the page			
   x = obj(i).GetROProperty("innerhtml") 
   print x 
Next

Ordinal Identifiers

Descriptive programming is used to write the script based on ordinal identifiers, which will enable QTP to act on those objects when two or more objects have the same properties.

' Using Location
Dim Obj
Set Obj = Browser("title:=.*google.*").Page("micclass:=Page")
Obj.WebEdit("name:=Test","location:=0").Set "ABC"
Obj.WebEdit("name:=Test","location:=1").Set "123"
 
' Index
Obj.WebEdit("name:=Test","index:=0").Set "1123"
Obj.WebEdit("name:=Test","index:=1").Set "2222"
 
' Creation Time
Browser("creationtime:=0").Sync
Browser("creationtime:=1").Sync
Browser("creationtime:=2").Sync

QTP - Automation Object Model

QTP itself can be automated using the COM interface that is provided by HP-QTP. Automation object model is a set of objects, methods, and properties that helps the testers to control the configuration settings and execute the scripts using the QTP interface. The Key Configurations/actions that can be controlled (but not limited to) are listed below −

  • Loads all the required add-ins for a test
  • Makes QTP visible while execution
  • Opens the Test using the specified location
  • Associates Function Libraries
  • Specifies the Common Object Sync Time out
  • Start and End Iteration
  • Enable/Disable Smart Identification
  • On Error Settings
  • Data Table Path
  • Recovery Scenario Settings
  • Log Tracking Settings

QTP 11.5x provides an exclusive documentation on Automation Object model that can be referred by navigating to "Start" >> "All Programs" >> "HP Software" >> "HP Unified Functional Testing" >> "Documentation" >> "Unified Functional Testing Automation Reference".

Generate AOM Script

A tester can generate AOM script from QTP itself, using the "Generate Script" option. Navigate to "Run" >> "Settings" >> "Properties" Tab >> "Generate Script" as shown below −

Automation Object Model

Example

' A Sample Script to Demostrate AOM
Dim App 'As Application
Set App = CreateObject("QuickTest.Application")
App.Launch
App.Visible = True

App.Test.Settings.Launchers("Web").Active = False
App.Test.Settings.Launchers("Web").Browser = "IE"
App.Test.Settings.Launchers("Web").Address = "http://easycalculation.com/"
App.Test.Settings.Launchers("Web").CloseOnExit = True

App.Test.Settings.Launchers("Windows Applications").Active = False
App.Test.Settings.Launchers("Windows Applications").Applications.RemoveAll
App.Test.Settings.Launchers("Windows Applications").RecordOnQTDescendants = True
App.Test.Settings.Launchers("Windows Applications").RecordOnExplorerDescendants = False
App.Test.Settings.Launchers("Windows Applications").RecordOnSpecifiedApplications = True

App.Test.Settings.Run.IterationMode = "rngAll"
App.Test.Settings.Run.StartIteration = 1
App.Test.Settings.Run.EndIteration = 1
App.Test.Settings.Run.ObjectSyncTimeOut = 20000
App.Test.Settings.Run.DisableSmartIdentification = False
App.Test.Settings.Run.OnError = "Dialog"

App.Test.Settings.Resources.DataTablePath = "<Default>"
App.Test.Settings.Resources.Libraries.RemoveAll

App.Test.Settings.Web.BrowserNavigationTimeout = 60000
App.Test.Settings.Web.ActiveScreenAccess.UserName = ""
App.Test.Settings.Web.ActiveScreenAccess.Password = ""

App.Test.Settings.Recovery.Enabled = True
App.Test.Settings.Recovery.SetActivationMode "OnError"
App.Test.Settings.Recovery.Add "D:\GUITest2\recover_app_crash.qrs", 
   "Recover_Application_Crash", 1
App.Test.Settings.Recovery.Item(1).Enabled = True 

''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
' System Local Monitoring settings
''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
App.Test.Settings.LocalSystemMonitor.Enable = false
''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
' Log Tracking settings
''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''''
With App.Test.Settings.LogTracking
   .IncludeInResults = False
   .Port = 18081 
   .IP = "127.0.0.1"
   .MinTriggerLevel = "ERROR"
   .EnableAutoConfig = False
   .RecoverConfigAfterRun = False
   .ConfigFile = ""
   .MinConfigLevel = "WARN" 
End With

QTP - Frameworks

A Framework defines a set of guidelines/best practices that enforces a set of standards, which makes it easy to use for the end users to work with. There are different types of automation frameworks and the most common ones are listed below −

  • Keyword-Driven Framework
  • Data-Driven Framework
  • Hybrid Framework

Keyword-Driven Framework

Keyword driven testing is a type of functional automation testing framework which is also known as table-driven testing or action word based testing.

In Keyword-driven testing, we use a table format, usually a spreadsheet, to define keywords or action words for each function that we would like to execute.

Keyword Driven testing in Automation Testing

Advantages

  • It is best suited for novice or a non-technical tester.

  • Enables writing tests in a more abstract manner using this approach.

  • Keyword driven testing allows automation to be started earlier in the SDLC even before a stable build is delivered for testing.

  • There is a high degree of reusability.

Disadvantages

  • Initial investment in developing the keywords and its related functionalities might take longer.

  • It might act as a restriction to the technically abled testers.

Data Driven Framework

Data-driven testing is creation of test scripts where test data and/or output values are read from data files instead of using the same hard-coded values each time the test runs. This way, the testers can test how the application handles various inputs effectively. It can be any of the following data files −

  • datapools
  • Excel files
  • ADO objects
  • CSV files
  • ODBC sources

Flow Diagram

Data Driven Testing can be best understood by the following diagram −

Keyword Driven testing in Automation Testing

Advantages

  • Data driven framework results in less amount of code
  • Offers greater flexibility for maintaining and fixing the scripting issues
  • Test Data can be developed

Disadvantages

  • Each script needs to be different to understand different sets of data.

Hybrid Framework

Hybrid Framework is a combination of Keyword driven and data Driven framework that can be best described using the following flow diagram.

Hybrid Framework in Automation Testing

Affecting Factors

Following are the parameters one should take into account while developing the framework. The affects factors are listed below −

  • Framework files should support versioning controlling software such as SVN, CVS, MS Source Control

  • Framework should support executing the scripts in different environments viz- QA, SAT, DEV

  • Upon Object changes, scripts should execute with minimal changes.

  • Framework should configure itself and take care of prerequisite such as creating folders/databases.

  • Framework should have robust reporting structure so that issues in the script/application can be easily spotted

  • Framework should have greater flexibility so that it should be easy to use

  • Framework should follow coding standards so that files, functions, and history of changes are maintained correctly.

In the next chapter, we will learn how to design a simple framework.

QTP - Designing Framework

Let us design a simple framework by taking a sample application. We will automate a few scenarios of the application under test and write reusable functions.

The sample application under test is "Calculator", a default application that is available as a part of Windows. Let us now create different components of a framework. Here, we will develop a hybrid framework and use Object Repository as it is fairly a simple application. However, this framework can be scaled to support a complex application as well.

The folder structure of the Framework is as shown below −

QTP Framework Folder Structure

Explanation of the folder structure −

  • Master Driver Script − The Script that drives the entire execution. It performs prerequisite and initial settings that are required for the execution.

  • Library Files − The Associated Functions that forms the Function Library.

  • Data Table − The Test Data that is required for the Execution.

  • Object Repository − The Objects and its properties that enable QTP to recognize the objects seamlessly.

  • Execution Logs − The Folder contains the execution log file with user functions and function execution history.

Master Driver Script

'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 
' MASTER DRIVER SCRIPT NAME    : Calculator 
' DESCRIPTION                  : Drivers Script to Execute Automated Test for 
   the Calculator  
' AUTHOR                       : Tutorials Point 
' DATE CREATED                 : 30-Dec-2013 
' OBJECT REPOSITORY ASSOCIATED : Calc.tsr 
' LIBRARY FILES ASSOCIATED     : calculator.qfl, Common.qfl 
' MODIFICATION LOG

' ---------------------------------------------------- 
' First Version       Tutorials point 
'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =  
Option Explicit  

Public ExecDrive  

' Get the Root folder of the Test  so that we can make use of relative paths. 
Dim x : x = Instr(Environment.Value("TestDir"),"Driver")-2 
ExecDrive = mid(Environment.Value("TestDir"),1,x)  

' Get the path of Libraries using relative to the current Drive 
Dim LibPath : LibPath = ExecDrive+"\Libraries\"  

' Dynamically Load the Function Libraries 
LoadFunctionLibrary LibPath + "Calculator.qfl", LibPath + "common_utils.qfl"   

' Capturing the Start Time 
' clscommon is the class object created in common.qfl library file 
clscommon.StartTime = Time()  

' Launching the Application 
SystemUtil.Run "C:\Windows\System32\Calc.exe" : wait (2)  

' Initialize the Data Table Path  
Dim FileName : FileName  = ExecDrive+"\TestData\Calculator.xls" 
Dim SheetSource : SheetSource  = "Calc_test" 
Dim SheetDest : SheetDest = "Global"  

' Import the DataTable into the QTP Script 
DataTable.ImportSheet  FileName , SheetSource , SheetDest   

' Object Repository Path 
Dim RepPath : RepPath = ExecDrive+"\Object_Repository\Calc.tsr" 
RepositoriesCollection.RemoveAll()  
RepositoriesCollection.Add(RepPath)   

' To Keep a Count on iteration 
Dim InttestIteration                   
Dim InttestRows : InttestRows = datatable.GetRowCount   

'  Fetching Date-TimeStamp which will be unique for Naming the Execution Log File 
clscommon.StrDateFormatted = day(date()) & "_" &  MonthName(Month(date()),true) &  
 "_" & YEAR(date())& "_"&hour(now)&"_"&minute(now)  

 ' Name the LogFile  
clscommon.StrLogFile = ExecDrive & "\Execution Logs\" &  
clscommon.StrDateFormatted & ".txt"   

' Create the Execution LogFile which captures the result 
clscommon.Fn_FileCreate(clscommon.StrLogFile)  

' Iniitialize the Parameters and all the relevant Test Details 
Call Fn_InitializeLogFile()  

' Kill all the previous calculator process  
Call fn_Kill_Process("calc.exe")  

For InttestIteration = 1 to InttestRows 
   datatable.SetCurrentRow InttestIteration  
   Dim StrExecute : StrExecute = Ucase(Trim(datatable.Value("Run","Global"))) 
   If StrExecute = "Y" Then  
      clscommon.Number1 = Trim(datatable.Value("Number_1","Global"))  
      clscommon.Number2 = Trim(datatable.Value("Number_2","Global"))  
      clscommon.Number3 = Trim(datatable.Value("Number_3","Global"))  
   
      clscommon.Number4 = Trim(datatable.Value("Number_4","Global"))  
      clscommon.Number5 = Trim(datatable.Value("Number_5","Global"))  
      clscommon.Number6 = Trim(datatable.Value("Number_6","Global"))  
   
      clscommon.Test_Case_ID  = 
         Trim(datatable.Value("Test_Case_ID","Global"))' 
            : clscommon.LogWrite "The Test Case Data is Located at :: " & tcDataPath 
      clscommon.tcScenario = 
         Trim(datatable.Value("Scenario","Global"))' 
            : clscommon.LogWrite "The Test Case Data is Located at :: " & tcDataPath 
      Dim  Expected_Val :  Expected_Val = 
         Trim(datatable.Value("Expected_Val","Global"))'                        
            :  clscommon.LogWrite "The Test Case Data is Located at :: " & tcDataPath 
   
      Select case clscommon.tcScenario  
         Case "Add" 
            clscommon.LogWrite "=== Inside the Test Set :: " & 
               clscommon.tcScenario & " ===" 
                  Call fnCalculate("+",Expected_Val) 
    
         Case "Subtract"   
            clscommon.LogWrite "=== Inside the Test Set :: " & 
               clscommon.tcScenario & " ===" 
                  Call fnCalculate("-",Expected_Val) 
    
         Case "Multiply"   
            clscommon.LogWrite "=== Inside the Test Set :: " & 
               clscommon.tcScenario & " ===" 
                  Call fnCalculate("*",Expected_Val) 
    
         Case "Divide"   
            clscommon.LogWrite "=== Inside the Test Set :: " & 
               clscommon.tcScenario & " ===" 
                  Call fnCalculate("/",Expected_Val) 
    
         Case "Sqrt"   
            clscommon.LogWrite "=== Inside the Test Set :: " & 
               clscommon.tcScenario & " ===" 
                  Call fnCalculate("sqt",Expected_Val) 
      End Select 
   End If  
Next  

' Calling the End Test to Add the result Footer in exec log file. 
Call fn_End_test()  

'  =====================  End of Master Driver Script ===================== 

Library Files

The Calculator Functions are written in a separate function file saved with the extension .qfl or .vbs. These functions are reusable across actions.

'  Calculator. Qfl File :: Associated Function Library for Calculator Master Driver  

'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =  
' FUNCTION NAME     : Fn_InitializeLogFile 
' DESCRIPTION       : Function to Write the Initial Values in the Log File 
' INPUT PARAMETERS  : varExecDrive,StrDB,StrUId,Strpwd,StrNewDB 
' OUTPUT PARAMETERS : NIL 
' RETURN VALUE      : Pass or Fail message 
' DATE CREATED      : 30-Dec-2013 
'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =  
Public Function Fn_InitializeLogFile() 
   clscommon.LogWrite "********************************************" 
   clscommon.LogWrite "Calc Automation Started" 
End Function 
'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =  
' FUNCTION NAME     : fnCalculate 
' DESCRIPTION       : Function to perform Arithmetic Calculations 
' INPUT PARAMETERS  : operator,Expected_Val 
' OUTPUT PARAMETERS : NIL 
' RETURN VALUE      : Pass or Fail message 
' DATE CREATED      : 30-Dec-2013 
'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =    
Function fnCalculate(operator,Expected_Val) 
   clscommon.LogWrite "Executing the Function 'fnCalculate' " 

   Window("Calculator").Activate 
    
   If Trim(clscommon.Number1) <> ""  Then
      Window("Calculator").WinButton(clscommon.Number1).Click 
   If Trim(clscommon.Number2) <> ""  Then 
      Window("Calculator").WinButton(clscommon.Number2).Click 
   If Trim(clscommon.Number3) <> ""  Then 
      Window("Calculator").WinButton(clscommon.Number3).Click 

   Window("Calculator").WinButton(operator).Click 
   If Trim(clscommon.Number4) <> ""  Then 
      Window("Calculator").WinButton(clscommon.Number4).Click 
   If Trim(clscommon.Number5) <> ""  Then 
      Window("Calculator").WinButton(clscommon.Number5).Click 
   If Trim(clscommon.Number6) <> ""  Then 
      Window("Calculator").WinButton(clscommon.Number6).Click 

   Window("Calculator").WinButton("=").Click 
   Dim ActualVal : ActualVal  = 
      Window("Calculator").WinEdit("Edit").GetROProperty("text") 
   clscommon.LogWrite "The Actual Value after the Math Operation is "& ActualVal 
  
   If Trim(ActualVal) = Trim(Expected_Val) Then 
      clscommon.WriteResult "Pass",  clscommon.Test_Case_ID , 
         clscommon.tcScenario , " Expected Value matches with Actual Value :: " 
            & ActualVal 
    
   Else 
      clscommon.WriteResult "Fail",  clscommon.Test_Case_ID , 
         clscommon.tcScenario , " Expected Value - " & Expected_Val & " Does NOT matches 
            with Actual Value :: " & ActualVal 
   End If 
    
   Window("Calculator").WinButton("C").Click 
    
   If Err.Number <> 0  Then 
      clscommon.LogWrite  "Execution Error : The Error Number is ::  " & 
         Err.Number & " The Error Description is " & Err.Description 
      Err.Clear 
   End If 
    
   clscommon.LogWrite "Exiting the Function 'fnCalculate' " 
End Function  

'= = = = = = = = = = = = = = = = = = = = = = = = = = = 
' FUNCTION NAME     : fn_Kill_Process 
' DESCRIPTION       : Function to Kill the process by name 
' INPUT PARAMETERS  : Application name to be killed 
' OUTPUT PARAMETERS : NIL 
' RETURN VALUE      : NIL 
' DATE CREATED      : 30-Dec-2013 
'= = = = = = = = = = = = = = = = = = = = = = = = = = =  
Function fn_Kill_Process(process) 
   Dim strComputer ,  strProcessToKill , objWMIService , colProcessstrComputer = "." 
   strProcessToKill = process 
    
   Set objWMIService = GetObject("winmgmts:" _& 
      "{impersonationLevel=impersonate}!\\" _& strComputer & "\root\cimv2") 
    
   Set colProcess = objWMIService.ExecQuery _("Select * from Win32_Process 
      Where Name = '" & strProcessToKill & "'") 
    
   count = 0 
   For Each objProcess in colProcess 
      objProcess.Terminate() 
      count = count + 1 
   Next 
End Function  

'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =  
' FUNCTION NAME     : fn_End_test 
' DESCRIPTION       : Function to finish the test Execution process 
' INPUT PARAMETERS  : Application name to be killed 
' OUTPUT PARAMETERS : NIL 
' RETURN VALUE      : NIL 
' DATE CREATED      : 20/Dec/2013 
'= = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 
Function fn_End_test() 
   clscommon.LogWrite "Status Message - Executing the Function 'fn_End_test' " 
    
   Window("Calculator").Close 
   On Error Resume Next 
    
   clscommon.StopTime = Time() 
   clscommon.ElapsedTime = DateDiff("n",clscommon.StartTime,clscommon.StopTime) 
   Dim Totaltests  
   Totaltests = clscommon.gintPassCount+ clscommon.gintFailCount
   clscommon.LogWrite "## # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # 
   clscommon.LogWrite "##  The Execution Start Time  ::  " & clscommon.StartTime 
   clscommon.LogWrite "##  The Execution End Time   ::  " & clscommon.StopTime 
   clscommon.LogWrite "##  The Time Elapsed ::   " & clscommon.ElapsedTime & " Minutes " 
   clscommon.LogWrite "##  The OS ::  " & Environment.Value("OS") 
   clscommon.LogWrite "##  The Total No of Test Cases Executed  ::  " & Totaltests 
   clscommon.LogWrite "##  The No. of Test Case Passed ::  " & clscommon.gintPassCount 
   clscommon.LogWrite "##  The No. of Test Case Failed ::  " & clscommon.gintFailCount 
   clscommon.LogWrite "## # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # # 
   SystemUtil.CloseDescendentProcesses 
End Function  
'  ===============   End of Calculator. Qfl   ============================= '

The other library file, which is 'common_utils.qfl' that contains the functions, which enables us to write the output to a text file.

Set clscommon = New OS_clsUtils  

'Creating a class file to handle global variables. 
Class OS_clsUtils 
   Dim StrLogFile 
   Dim StrDateFormatted 
   Dim Result 
    
   Dim  Number1, Number2 , Number3  
   Dim  Number4, Number5 , Number6  
   Dim Test_Case_ID , tcScenario 
   Dim StartTime, StopTime, ElapsedTime 
   
   Dim gintPassCount , gintFailCount , gintWarningCount ,  gintdoneCount,  
      gintinfoCount 
    
   Function Fn_FileCreate(strFileName) 
      Dim objFSO:  Set objFSO = CreateObject("Scripting.FileSystemObject") 
      On Error Resume Next 
      
      Dim objTextFile : Set objTextFile = objFSO.CreateTextFile(strFileName) 
      objTextFile.Close 
       
      Set objTextFile = Nothing 
      Set objFSO = Nothing 
   End Function 
    
   Function LogWrite(sMsg) 
      Const ForAppending = 8 
       
      Dim objFSO : Set objFSO = CreateObject("scripting.FileSystemObject") 
      
      Dim objTextFile : Set objTextFile = objFSO.OpenTextFile 
         (clscommon.StrLogFile, ForAppending, True) 
       
      objTextFile.WriteLine day(date()) & "/" &  MonthName(Month(date()),true) 
         &  "/" & YEAR(date()) & " " & time & ": " & sMsg 
      objTextFile.Close 
       
      Set objTextFile = Nothing 
      Set objFSO = Nothing 
   End Function 
    
   Function WriteResult(strStatus,functionName,functionDescription,Result) 
      Const ForAppending = 8 
      Dim objFSO : Set objFSO = CreateObject("scripting.FileSystemObject") 
      Dim objTextFile : Set objTextFile = objFSO.OpenTextFile 
         (clscommon.StrLogFile, ForAppending, True) 
       
      objTextFile.WriteLine day(date()) & "/" &  MonthName(Month(date()),true) 
         &  "/" & YEAR(date()) & " " & time & ": " & "  
            * * * * * * Test Case Exec Details  * * * * * " 
      
      objTextFile.WriteLine day(date()) & "/" &  MonthName(Month(date()),true) 
         &  "/" & YEAR(date()) & " " & time & ": " & " Test staus :: " & strStatus 
      objTextFile.WriteLine day(date()) & "/" &  MonthName(Month(date()),true) 
         &  "/" & YEAR(date()) & " " & time & ": " & " Tese ID ::  " & functionName 
      objTextFile.WriteLine day(date()) & "/" &  MonthName(Month(date()),true) 
         &  "/" & YEAR(date()) & " " & time & ": " & " Test Description :: " 
            & functionDescription 
      objTextFile.WriteLine day(date()) & "/" &  MonthName(Month(date()),true) 
         &  "/" & YEAR(date()) & " " & time & ": " & " Test Result Details :: " & Result 
      objTextFile.WriteLine day(date()) & "/" &  MonthName(Month(date()),true) 
         &  "/" & YEAR(date()) & " " & time & ": " & "  
            * * * * * * * * * * * * * * * * * * * * * * * *  * * * * * * * * * * * " 
      objTextFile.Close 
       
      Set objTextFile = Nothing  
      Set objFSO = Nothing 
       
      Select Case Lcase(strStatus) 
         Case "pass" 
            gintPassCount = gintPassCount + 1 
          
         Case "fail" 
            gintFailCount = gintFailCount+1 
      End Select 
   End Function 
End Class 
'   =====================   End of common_Utils.qfl ===================== 

Object Repository

Object Repository has got all the objects that the user would be acting upon. The image given below shows the list of all objects added into the repository with the name calc.tsr

OR of the AUT

Data Table

DataTable contains the keywords, which drive the tests and also Test the data with which QTP will act on the objects.

Data Table used in the Framework

The Execution Log

The Execution log file or output file contains user actions and function log, which will enable the testers to debug upon script failures.

Data Table used in the Framework

8/Jan/2014 5:09:16 PM: ************************************************* 
8/Jan/2014 5:09:16 PM: Calc Automation Started 
8/Jan/2014 5:09:16 PM: === Inside the Test Set  ::   Add  === 
8/Jan/2014 5:09:16 PM: Executing the Function 'fnCalculate'  
8/Jan/2014 5:09:17 PM: The Actual Value after the Math Operation is 949.  
8/Jan/2014 5:09:17 PM:  * * * * * * Test Case Exec Details  * * * * *  
8/Jan/2014 5:09:17 PM: Test staus :: Pass 
8/Jan/2014 5:09:17 PM: Tese ID ::  TC_001 
8/Jan/2014 5:09:17 PM: Test Description :: Add 
8/Jan/2014 5:09:17 PM: Test Result Details ::  Expected Value matches with Actual 
   Value :: 949.  
8/Jan/2014 5:09:17 PM: * * * * * * * * * * * * * * * * * * * * * * * *  * * 
* * * * * * * * * 
  
8/Jan/2014 5:09:17 PM: Exiting the Function 'fnCalculate'  
8/Jan/2014 5:09:17 PM: === Inside the Test Set  ::   Subtract  === 
8/Jan/2014 5:09:17 PM: Executing the Function 'fnCalculate'  
8/Jan/2014 5:09:17 PM: The Actual Value after the Math Operation is 415.  
8/Jan/2014 5:09:17 PM: * * * * * * Test Case Exec Details  * * * * *  
8/Jan/2014 5:09:17 PM: Test staus :: Pass 
8/Jan/2014 5:09:17 PM: Tese ID ::  TC_002 
8/Jan/2014 5:09:17 PM: Test Description :: Subtract 
8/Jan/2014 5:09:17 PM: Test Result Details ::  Expected Value matches with Actual 
   Value :: 415.  
8/Jan/2014 5:09:17 PM: * * * * * * * * * * * * * * * * * * * * * * * *  * * * 
* * * * * * * *

8/Jan/2014 5:09:17 PM: Exiting the Function 'fnCalculate'  
8/Jan/2014 5:09:17 PM: === Inside the Test Set  ::   Multiply  === 
8/Jan/2014 5:09:17 PM: Executing the Function 'fnCalculate'  
8/Jan/2014 5:09:18 PM: The Actual Value after the Math Operation is 278883.  
8/Jan/2014 5:09:18 PM: * * * * * * Test Case Exec Details  * * * * *  
8/Jan/2014 5:09:18 PM: Test staus :: Pass 
8/Jan/2014 5:09:18 PM: Tese ID ::  TC_003 
8/Jan/2014 5:09:18 PM: Test Description :: Multiply 
8/Jan/2014 5:09:18 PM:  Test Result Details ::  Expected Value matches with 
   Actual Value :: 278883.  
8/Jan/2014 5:09:18 PM: * * * * * * * * * * * * * * * * * * * * * * * *  * * * 
* * * * * * * *   

8/Jan/2014 5:09:18 PM: Exiting the Function 'fnCalculate'  
8/Jan/2014 5:09:18 PM: === Inside the Test Set  ::   Divide  === 
8/Jan/2014 5:09:18 PM: Executing the Function 'fnCalculate'  
8/Jan/2014 5:09:19 PM: The Actual Value after the Math Operation is 3.  
8/Jan/2014 5:09:19 PM: * * * * * * Test Case Exec Details  * * * * *  
8/Jan/2014 5:09:19 PM: Test staus :: Pass 
8/Jan/2014 5:09:19 PM: Tese ID ::  TC_004 
8/Jan/2014 5:09:19 PM: Test Description :: Divide 
8/Jan/2014 5:09:19 PM: Test Result Details ::  Expected Value matches with Actual 
   Value :: 3.  
8/Jan/2014 5:09:19 PM: * * * * * * * * * * * * * * * * * * * * * * * *  * * * 
* * * * * * * * 
  
8/Jan/2014 5:09:19 PM: Exiting the Function 'fnCalculate'  
8/Jan/2014 5:09:19 PM: === Inside the Test Set  ::   Sqrt  === 
8/Jan/2014 5:09:19 PM: Executing the Function 'fnCalculate'  
8/Jan/2014 5:09:20 PM: The Actual Value after the Math Operation is 10.  
8/Jan/2014 5:09:20 PM: * * * * * * Test Case Exec Details  * * * * *  
8/Jan/2014 5:09:20 PM: Test staus :: Pass 
8/Jan/2014 5:09:20 PM: Tese ID ::  TC_005 
8/Jan/2014 5:09:20 PM: Test Description :: Sqrt 
8/Jan/2014 5:09:20 PM: Test Result Details ::  Expected Value matches with Actual 
   Value :: 10.  
8/Jan/2014 5:09:20 PM: * * * * * * * * * * * * * * * * * * * * * * * *  * * * * 
* * * * * * * 

8/Jan/2014 5:09:20 PM: Exiting the Function 'fnCalculate'  
8/Jan/2014 5:09:20 PM: Status Message - Executing the Function 'fn_Finish_test'  
8/Jan/2014 5:09:20 PM: ## # # # # # # # # # # # # # # # # # # # # # # # # # 
# # # # # #  
8/Jan/2014 5:09:20 PM: ##  The Execution Start Time  ::  5:09:14 PM 
8/Jan/2014 5:09:20 PM: ##  The Execution End Time   ::  5:09:20 PM 
8/Jan/2014 5:09:20 PM: ##  The Time Elapsed ::   0 Minutes  
8/Jan/2014 5:09:20 PM: ##  The OS ::  Microsoft Windows Vista Server 
8/Jan/2014 5:09:20 PM: ##  The Total No of Test Cases Executed  ::  25 
8/Jan/2014 5:09:20 PM: ##  The No. of Test Case Passed ::  25 
8/Jan/2014 5:09:20 PM: ##  The No. of Test Case Failed ::   
8/Jan/2014 5:09:20 PM: ## # # # # # # # # # # # # # # # # # # # # # # # # # 
# # # # # #